Title of article :
A liquid scintillator detector with wavelength-shifting fibre readout
Author/Authors :
Doucet، نويسنده , , M and Fabre، نويسنده , , J.-P and Grégoire، نويسنده , , G and Panman، نويسنده , , J and Zucchelli، نويسنده , , P، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
8
From page :
545
To page :
552
Abstract :
A technique based on liquid scintillator with wavelength-shifting fibre readout is interesting for large-mass neutrino detectors. In this paper, we present the first results obtained with a laboratory prototype assembled at CERN. In the configuration tested, a large light yield has been observed and attenuation lengths of the order of 3.2 m have been measured. As a comparison, we also measured the attenuation length of the fibres in air using the same setup. No significant difference in attenuation length between the fibres in air and in liquid was measured.
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2000
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2187918
Link To Document :
بازگشت