Title of article :
Non-destructive assay measurement for the verification of uranium oxide powders
Author/Authors :
Badawy، نويسنده , , I and Youssef، نويسنده , , A.S and El-Kazzaz، نويسنده , , SH and El-Gammal، نويسنده , , W.A، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
8
From page :
621
To page :
628
Abstract :
A passive non-destructive assay technique is employed in the present investigation for precise measurement of 235U enrichment of uranium oxide powders used for nuclear fuel fabrication. The technique would not require nuclear material Standards for the measurement of 235U enrichment. It uses a gamma-ray spectrometer composed of a high-resolution germanium detector system and associated electronics. A new mathematical analysis – based on Monte Carlo calculations – has been developed for the estimation of 235U enrichment. The obtained results are found to be of comparable accuracy with the results obtained by the relative methods which necessitate the use of nuclear material Standards. This work would be very useful for nuclear material control at the production level, and for inventory verification and safeguards purposes.
Keywords :
Monte Carlo , Self-attenuation , efficiency , Uranium enrichment , Solid angle