Author/Authors :
Arnaldi، نويسنده , , R and Baldit، نويسنده , , A and Barret، نويسنده , , V and Bastid، نويسنده , , N and Blanchard، نويسنده , , G and Chiavassa، نويسنده , , E and Cortese، نويسنده , , P and Crochet، نويسنده , , P and Dellacasa، نويسنده , , G and Marco، نويسنده , , N.De and Dupieux، نويسنده , , P and Espagnon، نويسنده , , B and Fargeix، نويسنده , , J and Ferretti، نويسنده , , A and Gallio، نويسنده , , M and Lamoine، نويسنده , , L and Luquin، نويسنده , , L ، نويسنده ,
Abstract :
The use of phenolic or melaminic bakelite as RPC electrodes is widespread. The electrode resistivity is an important parameter for the RPC performance. As recent studies pointed out, the bakelite resistivity changes with temperature and is influenced by humidity. In order to gain a quantitative understanding on the influence of temperature and humidity on RPC electrodes, we assembled an apparatus to measure resistivity in well-controlled conditions. A detailed description of the experimental set-up as well as the first resistivity measurements for various laminates in different environmental conditions are presented.
Keywords :
Bakelite , resistivity , Temperature , Humidity