Title of article :
Studies of the response of the prototype CMS hadron calorimeter, including magnetic field effects, to pion, electron, and muon beams
Author/Authors :
Abramov، نويسنده , , V.V. and Acharya، نويسنده , , B.S. and Akchurin، نويسنده , , N. and Atanasov، نويسنده , , I. and Baiatian، نويسنده , , G. and Ball، نويسنده , , A. and Banerjee، نويسنده , , S. and Banerjee، نويسنده , , S. and de Barbaro، نويسنده , , P. and Barnes، نويسنده , , V. and Bencze، نويسنده , , G. and Bodek، نويسنده , , A. and Booke، نويسنده , , M. and Budd، نويسنده , , H. and Cremaldi، نويسنده , , L. and Cushman، نويسنده , , P. an، نويسنده ,
Abstract :
We report on the response of a prototype CMS hadron calorimeter module to charged particle beams of pions, muons, and electrons with momenta up to 375 GeV/c. The data were taken at the H2 and H4 beamlines at CERN in 1995 and 1996. The prototype sampling calorimeter used copper absorber plates and scintillator tiles with wavelength shifting fibers for readout. The effects of a magnetic field of up to 3 T on the response of the calorimeter to muons, electrons, and pions are presented, and the effects of an upstream lead tungstate crystal electromagnetic calorimeter on the linearity and energy resolution of the combined calorimetric system to hadrons are evaluated. The results are compared with Monte Carlo simulations and are used to optimize the choice of total absorber depth, sampling frequency, and longitudinal readout segmentation.