Title of article :
Measurement of absorbed dose distributions in a plastic phantom irradiated by 40- and 65-MeV quasi-monoenergetic neutrons
Author/Authors :
Nakane، نويسنده , , Y and Sakamoto، نويسنده , , Y، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
13
From page :
552
To page :
564
Abstract :
In order to validate dose evaluation methods for radiation shielding design of accelerator facilities, absorbed dose distributions in a plastic phantom of 30×30×30 cm3 slab were measured for 40- and 65-MeV quasi-monoenergetic neutrons with a tissue-equivalent proportional counter and a tissue-equivalent ionization chamber. The measured distributions were compared with the calculated ones from the energy deposition of charged particles and neutron energy spectra by using the Monte Carlo codes, HETC-3STEP and MORSE-CG/KFA, respectively. As a result, it was revealed that the calculation method used in the present work was applicable to absorbed dose evaluation for intermediate energy neutrons with high accuracy.
Keywords :
Absorbed Dose , Plastic phantom , Monte Carlo codes , TEPC , 40- and 65-MeV quasi-monoenergetic neutron
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2001
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2189236
Link To Document :
بازگشت