Abstract :
Ion exchange resin used in this work was styrene-divinylbenzene co-polymer with sulfonic acid group as a strong acid cation resin. This resin is particularly well suited for the removal of water hardness. In water treatment, commonly used softening processes are chemical precipitation and ion exchange. In this study, a combination of ultrasound and ion exchange was applied for reducing the hardness of water. The rate of exchange or kinetics of ion exchange is governed by several parameters. Therefore, important variables such as intensity of ultrasound, amount of resin, concentration of ions and contact time were investigated. The experimental data related to the removal of magnesium and calcium ions were fitted properly with Langmuir model. The kinetic of removal for both ions was pseudo-first-order. In point of mechanism, the internal porous and film diffusion were both effective in the process. The capacity of sorption and the velocity of removal were higher in the presence of ultrasound than control method and this is related to the cavitation process.
Keywords :
Water Hardness , Cavitation , Ion exchange , Langmuir model , Ultrasound