• Title of article

    Prototype performance and design of the ATLAS pixel sensors

  • Author/Authors

    Hügging، نويسنده , , F. and Gِكling، نويسنده , , C. and Klaiber-Lodewigs، نويسنده , , J. and Wüstenfeld، نويسنده , , J. and Wunstorf، نويسنده , , R.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    6
  • From page
    77
  • To page
    82
  • Abstract
    Silicon pixel sensors for the ATLAS Pixel Detector have been successfully developed. The main attention for the design was given to survivability in the harsh radiation environment of LHC up to a fluence of 1015neq/cm2 during 10 years of operation. This leads to the need of long term operation at several hundreds of volts, partially depleted while maintaining good charge collection, small cell size and thin sensors reducing the multiple scattering. Additionally, a bias grid for testing the sensors before assembly under realistic bias conditions is implemented to allow a quality assurance.
  • Keywords
    detector , Pixel sensor , n-Side isolation , Silicon , sensor design , ATLAS
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2001
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2191141