Title of article :
Revolver undulator for BL15XU at SPring-8
Author/Authors :
Hara، نويسنده , , T. and Tanaka، نويسنده , , T. and Seike، نويسنده , , T. and Bizen، نويسنده , , T. and Maréchal، نويسنده , , X. and Nisawa، نويسنده , , A. and Fukushima، نويسنده , , S. and Yoshikawa، نويسنده , , H. and Kitamura، نويسنده , , H.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
4
From page :
161
To page :
164
Abstract :
We have developed and installed a revolver type undulator for a contract beamline (BL15XU) at SPring-8. Since wide energy range photons (0.5–60 keV) are used for the research in advanced materials at BL15XU, the revolver undulator has two pairs of undulator magnet arrays; one is a planar undulator for X-ray radiation and the other is a helical undulator for soft X-ray radiation. The two undulators are mounted on the same top and bottom rotatable magnet beams by 90°, and the beamline users can switch the undulators at anytime without any observable effect on the electron beam orbit and the photon beam position.
Keywords :
Revolver undulator , Helical undulator , Insertion device , Undulator
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2001
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2191672
Link To Document :
بازگشت