Title of article :
Blade-type X-ray beam position monitors for SPring-8 undulator beamlines
Author/Authors :
Aoyagi، نويسنده , , H. and Kudo، نويسنده , , T. and Kitamura، نويسنده , , H.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
The X-ray beam position monitors had been designed and installed for SPring-8 insertion device beamlines. These monitors are being utilized for photon beam diagnostics. The beam from the standard undulator in SPring-8 has the total power of 11 kW and the power density of 470 kW/mrad2, typically. Each monitor has four CVD diamond blades coated with metal for detector heads. We have already introduced three styles of monitors to match various insertion devices in SPring-8. A standard style, or a fixed-blade style, is used mainly for a standard in-vacuum undulator beamlines. A horizontal-blade-drive style and a four-blade-drive style are used for beamlines of a wiggler and a twin helical undulator that have wide power distributions, and for figure-8 undulators that have asymmetric power distributions, respectively. This report describes the design and the structure of these monitors and the beam-tests for the photon beam diagnostics in detail.
Keywords :
X-ray beam position monitor , CVD diamond blade , Photoemission , Beam diagnostics , Synchrotron radiation facility SPring-8 , Insertion device beamline
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A