Title of article :
Evaluation of neutron spectrometer techniques for ITER using synthetic data
Author/Authors :
Andersson Sundén، نويسنده , , E. and Ballabio، نويسنده , , L. and Cecconello، نويسنده , , M. and Conroy، نويسنده , , S. and Ericsson، نويسنده , , G. and Johnson، نويسنده , , M.Gatu and Gorini، نويسنده , , G. and Hellesen، نويسنده , , C. and Ognissanto، نويسنده , , F. and Ronchi، نويسنده , , E. and Sjِstrand، نويسنده , , H. and Tardocchi، نويسنده , , M. and Weiszflog، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
10
From page :
62
To page :
71
Abstract :
A neutron spectrometer at ITER is expected to provide estimates of plasma parameters such as ion temperature, Ti, fuel ion ratio, nt/nd, and Qthermal/Qtot, with 10–20% precision at a time resolution, Δt, of at least 100 ms. The present paper describes a method for evaluating different neutron spectroscopy techniques based on their instrumental response functions and synthetic measurement data. We include five different neutron spectrometric techniques with realistic response functions, based on simulations and measurements where available. The techniques are magnetic proton recoil, thin-foil proton recoil, gamma discriminating organic scintillator, diamond and time-of-flight. The reference position and line of sight of a high resolution neutron spectrometer on ITER are used in the study. ITER plasma conditions are simulated for realistic operating scenarios. The ITER conditions evaluated are beam and radio frequency heated and thermal deuterium–tritium plasmas. Results are given for each technique in terms of the estimated time resolution at which the parameter determination can be made within the required precision (here 10% for Ti and the relative intensities of NB and RF emission components). It is shown that under the assumptions made, the thin-foil techniques out-perform the other spectroscopy techniques in practically all measurement situations. For thermal conditions, the range of achieved Δt in the determination of Ti varies in time scales from ms (for the magnetic and thin-foil proton recoil) to s (for gamma discriminating organic scintillator).
Keywords :
neutron spectroscopy , Neutron spectrometry , ITER , High resolution neutron spectrometer , Time resolution
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2013
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2193443
Link To Document :
بازگشت