Title of article :
Characterization of neutron irradiated silicon microstrip detectors
Author/Authors :
Buffini، نويسنده , , A and Busoni، نويسنده , , S and Catacchini، نويسنده , , E and Civinini، نويسنده , , C and DʹAlessandro، نويسنده , , R and Focardi، نويسنده , , E and Lenzi، نويسنده , , M and Meschini، نويسنده , , M and Minelli، نويسنده , , C and Parrini، نويسنده , , G، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
5
From page :
734
To page :
738
Abstract :
Radiation effects on silicon microstrip detectors have been investigated on sensors similar to the ones that will be installed in the forward tracker of CMS. Sensors have been built starting from a high resistivity (about 6 kΩ cm) n-type substrate, 〈1 1 1〉 crystal lattice orientation. Some of the wafers have been exposed to a neutron beam with a 1 MeV equivalent neutron fluence of 1.1×1014 neutron/cm2. Depletion voltage, reverse current, bulk and interstrip capacitance have been measured in laboratory before and after irradiation, directly on the full size structures. Detectors built with these structures have then been tested with a 90Sr source in laboratory. Device properties and performances with respect to signal to noise ratio are presented, emphasizing their dependence on irradiation.
Keywords :
Silicon , Tracker , microstrip , detector , Radiation hardness
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2002
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2193630
Link To Document :
بازگشت