Title of article :
Response of AGATA segmented HPGe detectors to gamma rays up to 15.1 MeV
Author/Authors :
Crespi، نويسنده , , F.C.L. and Avigo، نويسنده , , R. and Camera، نويسنده , , F. and Akkoyun، نويسنده , , S. and Ataç، نويسنده , , A. and Bazzacco، نويسنده , , D and Bellato، نويسنده , , M. and Benzoni، نويسنده , , G. Di Blasi، نويسنده , , N. and Bortolato، نويسنده , , D. and Bottoni، نويسنده , , S. and Bracco، نويسنده , , Stuart A. and Brambilla، نويسنده , , S. and Bruyneel، نويسنده , , B. and Ceruti، نويسنده , , S. and Ciema?a، نويسنده , , M. and Coelli، نويسنده , , S. and Eberth، نويسنده , , J. and Fanin، نويسنده , , C. and Farnea، نويسنده , , E. and Gadea، نويسنده , , A. and Giaz، نويسنده , , A and Gottardo، نويسنده , , A. and Hess، نويسنده , , H. and Kmiecik، نويسنده , , M. and Leoni، نويسنده , , S. P. Maj، نويسنده , , A. and Mengoni، نويسنده , , D. and Michelagnoli، نويسنده , , C. and Million، نويسنده , , B. and Montanari، نويسنده , , D. and Nicolini، نويسنده , , R. and Pellegri، نويسنده , , L. and Recchia، نويسنده , , F. and Reiter، نويسنده , , P. and Riboldi، نويسنده , , S. and Ur، نويسنده , , C.A. and Vandone، نويسنده , , V. and Valiente-Dobon، نويسنده , , J.J. and Wieland، نويسنده , , O. and Wiens، نويسنده , , A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
8
From page :
47
To page :
54
Abstract :
The response of AGATA segmented HPGe detectors to gamma rays in the energy range 2–15 MeV was measured. The 15.1 MeV gamma rays were produced using the reaction d(11B,nγ)12C at Ebeam=19.1 MeV, while gamma rays between 2 and 9 MeV were produced using an Am–Be–Fe radioactive source. The energy resolution and linearity were studied and the energy-to-pulse-height conversion resulted to be linear within 0.05%.Experimental interaction multiplicity distributions are discussed and compared with the results of Geant4 simulations. It is shown that the application of gamma-ray tracking allows a suppression of background radiation caused by n-capture in Ge nuclei. Finally the Doppler correction for the 15.1 MeV gamma line, performed using the position information extracted with Pulse-shape analysis is discussed.
Keywords :
Pulse-shape and gamma-ray tracking algorithms , Semiconductor detector performance and simulations , AGATA , HPGe detectors , Gamma-ray spectroscopy , Gamma-ray tracking
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2013
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2193740
Link To Document :
بازگشت