Title of article :
Optimization of integration limit in the charge comparison method based on signal shape function
Author/Authors :
Wang، نويسنده , , Zhonghai and Zeng، نويسنده , , Jun and Zhu، نويسنده , , Tonghua and Wang، نويسنده , , Yudong and Yang، نويسنده , , Chaowen and Zhou، نويسنده , , Rong، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
5
From page :
5
To page :
9
Abstract :
A novel method is proposed to analyze neutron and gamma-ray signal shapes in liquid scintillation detectors. Specifically, the signal shape functions for a BC501 detector were characterized and a statistical model was used to analyze the discrimination of neutrons and gamma rays. The model varied the starting points of tail integration in the charge comparison method (CCM), and an optimized starting point was determined. Experimental measurements were performed to verify the model, and the results indicated good agreement. For a BC501 scintillator with 8.07 ns and 74.63 ns decay time constants we found optimal time to start the tail integration at 24 ns past the decay maximum.
Keywords :
Signal shape function , Pulse shape discrimination , Charge comparison method , BC501 , n–? discrimination
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2014
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2196180
Link To Document :
بازگشت