Title of article :
Development of a silicon micro-strip detector for tracking high intensity secondary beams
Author/Authors :
Kiuchi، نويسنده , , R. and Asano، نويسنده , , H. L. HASEGAWA، نويسنده , , S. and Honda، نويسنده , , R. and Ichikawa، نويسنده , , Y. and Imai، نويسنده , , Kyoung K. and Joo، نويسنده , , C.W. and Nakazawa، نويسنده , , K. and Sako، نويسنده , , H. and Sato، نويسنده , , S. and Shirotori، نويسنده , , K. and Sugimura، نويسنده , , H. and Tanida، نويسنده , , K. and Watabe، نويسنده , , T.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
5
From page :
399
To page :
403
Abstract :
A single-sided silicon micro-strip detector (SSD) has been developed as a tracking detector for hadron experiments at J-PARC where secondary meson beams with intensities of up to 108 Hz are available. The performance of the detector has been investigated and verified in a series of test beam experiments in the years 2009–2011. The hole mobility was deduced from the analysis of cluster events. The beam rate dependence was measured in terms of timing resolution, signal-to-noise ratio, and hit efficiency. This paper describes the detector with its read-out system, details of the test experiments, and discusses the performance achieved.
Keywords :
Micro-strip , Tracker , Beam test , DAQ , Silicon detector
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2014
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2196306
Link To Document :
بازگشت