Title of article :
Performance analysis for the CALIFA Barrel calorimeter of the R3B experiment
Author/Authors :
Alvarez-Pol، نويسنده , , H. and Ashwood، نويسنده , , N. and Aumann، نويسنده , , T. and Bertini، نويسنده , , D. and Cabanelas، نويسنده , , P. and Casarejos، نويسنده , , E. and Cederkall، نويسنده , , J. and Cortina-Gil، نويسنده , , D. and Dيaz Fernلndez، نويسنده , , P. Cerda-Duran، نويسنده , , I. and Fiori، نويسنده , , Claudia E. and Galaviz-Hernلndez، نويسنده , , D. and Labiche، نويسنده , , M. and Nacher، نويسنده , , E. and Pietras، نويسنده , , B. and Savran، نويسنده , , D. and Tengblad، نويسنده , , O. and Teubig، نويسنده , , P.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
14
From page :
453
To page :
466
Abstract :
The CALIFA calorimeter is an advanced detector for gamma rays and light charged particles, accordingly optimized for the demanding requirements of the physics programme proposed for the R3B facility at FAIR. The multipurpose character of CALIFA is required to fulfil challenging demands in energy resolution (5–6% at 1 MeV for gamma rays) and efficiency. Charged particles, e.g. protons of energies up to 320 MeV in the Barrel section, should also be identified with an energy resolution better to 1%. is divided into two well-separated sections: a “Forward EndCap” and a cylindrical “Barrel” covering an angular range from 43.2° to 140.3°. The Barrel section, based on long CsI(Tl) pyramidal frustum crystals coupled to large area avalanche photodiodes (LAAPDs), attains the requested high efficiency for calorimetric purposes. The construction of the CALIFA Demonstrator, comprising 20% of the total detector, has already been initiated, and commissioning experiments are expected for 2014. sessment of the capabilities and expected performance of the detector elements is a crucial step in their design, along with the prototypes evaluation. For this purpose, the Barrel geometry has been carefully implemented in the simulation package R3BRoot, including easily variable thicknesses of crystal wrapping and carbon fibre supports. A complete characterization of the calorimeter response (including efficiency, resolution, evaluation of energy and reconstruction losses) under different working conditions, with several physics cases selected to probe the detector performance over a wide range of applications, has been undertaken. Prototypes of different sections of the CALIFA Barrel have been modeled and their responses have been evaluated and compared with the experimental results. The present paper summarizes the outcome of the simulation campaign for the entire Barrel section and for the corresponding prototypes tested at different European installations.
Keywords :
Calorimetry , proton detection , Gamma detection , Exotic beams , Fast beams , Simulation
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2014
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2196813
Link To Document :
بازگشت