Title of article
Active pixel detector for ion beam profiling
Author/Authors
Marchal، نويسنده , , J and Passmore، نويسنده , , M.S and Abdalla، نويسنده , , M and Berg، نويسنده , , J.van den and Nejim، نويسنده , , A and Fr?jdh، نويسنده , , Ch and O’Shea، نويسنده , , V and Smith، نويسنده , , K.M and Rahman، نويسنده , , M، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
8
From page
224
To page
231
Abstract
The use of ion implanters has been vital to the downward scaling of device dimensions in silicon technology. To achieve good process control, the ion beam characteristics within the implanter must be well known. Hybrid pixel technology is advanced as a possible solution to the problem of real-time ion beam profiling and dosimetry. The proof-of-principle prototype detector is described. The read-out electronics comprises a charge integrating chip designed in Europractice. The detector has been tested in an argon ion beam. The results show real-time beam profile acquisition and current measurement. The effects of secondary electron emission are qualitatively observed for different beam energies and must be addressed for accurate beam profiling.
Keywords
Implanter , Ion Beam , detector , pixel , Profiler
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2002
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2196846
Link To Document