Title of article
Large liquid-scintillator trackers for neutrino experiments
Author/Authors
Benussi، نويسنده , , R. and Bruski، نويسنده , , N and DʹAmbrosio، نويسنده , , N and Déclais، نويسنده , , Y and Dupraz، نويسنده , , J and Fabre، نويسنده , , J.-P and Fanti، نويسنده , , V and Forton، نويسنده , , E and Frekers، نويسنده , , D and Frenkel، نويسنده , , A and Girerd، نويسنده , , C and Golovkin، نويسنده , , S.V and Gregoire، نويسنده , , G and Harrison، نويسنده , , K and Jonkmans، نويسنده , , G and Jonsson، نويسنده , , P and Katsanevas، نويسنده , , S and Kreslo، نويسنده , , I and Marteau، نويسنده , , J and Martellotti، نويسنده , , G and Martinez، نويسنده , , S and Medvedkov، نويسنده , , A.M and Moret، نويسنده , , G and Niwa، نويسنده , , K and Novikov، نويسنده , , V and Beek، نويسنده , , G.Van and Penso، نويسنده , , G and Vasilʹchenko، نويسنده , , V.G and Vuilleumier، نويسنده , , J.-L and Wilquet، نويسنده , , G and Zucchelli، نويسنده , , P، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
14
From page
503
To page
516
Abstract
Results are given on tests of large particle trackers for the detection of neutrino interactions in long-baseline experiments. Module prototypes have been assembled using TiO2-doped polycarbonate panels. These were subdivided into cells of ∼1 cm2 cross-section and 6 m length, filled with liquid scintillator. A wavelength-shifting fibre inserted into each cell captured a part of the scintillation light emitted when a cell was traversed by an ionizing particle. Two different fibre-readout systems have been tested: an optoelectronic chain comprising an image intensifier and an electron-bombarded CCD (EBCCD); and a hybrid photodiode (HPD). New, low-cost liquid scintillators have been investigated for applications in large underground detectors. Testbeam studies have been performed using a commercially available liquid scintillator. The number of detected photoelectrons for minimum-ionizing particles crossing a module at different distances from the fibre readout end was 6–12 with the EBCCD chain and a mirror at the non-readout end; 4–10 with the HPD and no mirror. The light-attenuation lengths in the fibres were ∼9.4 m with the EBCCD and ∼6.4 m with the HPD. The detector response to electron showers has also been measured. After ten radiation lengths of lead, the transverse position of the incoming electron was determined with a precision of a few millimetres for electrons of 4 GeV, and with a precision of 1.5–2.0 cm for electrons of 1 GeV.
Keywords
Tracking and position-sensitive detectors , Scintillation detectors , Liquid scintillators , EBCCD
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2002
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2197123
Link To Document