Title of article :
Automation of the particle dosimetry and the dose application for radiobiological experiments at a vertical proton beam
Author/Authors :
Winfried and Mِrtel، نويسنده , , H and Georgi، نويسنده , , J and Eyrich، نويسنده , , W and Fritsch، نويسنده , , M and Distel، نويسنده , , L، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
6
From page :
503
To page :
508
Abstract :
A facility with a vertical beam for radiobiological experiments with low-energy protons has been setup at the Tandem accelerator at Erlangen. This energy region is optimal to investigate the biological effects of the linear energy transfer in the Bragg region under physiological conditions. A new automated data acquisition system for dosimetry and monitoring based on a personal computer was developed and optimized for this setup. A specially designed sample holder offers possibilities of cooling or changing of atmosphere during irradiation. First irradiations of biological samples have shown the functionality of the setup.
Keywords :
Vertical beamline , Beam diagnosis , Radiobiological experiments , Particle dosimetry
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2002
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2197218
Link To Document :
بازگشت