Title of article
Development and evaluation of a four-channel digital flash X-ray imaging system
Author/Authors
Yi، نويسنده , , Wang and Jianping، نويسنده , , Cheng and Yuanjing، نويسنده , , Li and Hui، نويسنده , , Tian and Hongliang، نويسنده , , Du، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
8
From page
496
To page
503
Abstract
A four-channel digital flash X-ray imaging system has been developed in our lab. The four flash X-ray heads and four detectors can be used to obtain four radiographic images at four time intervals of an explosion and ballistic trajectory. The cascaded imaging system mainly consists of three parts: (1) a phosphor screen to convert incident X-rays into visible photons; (2) a lens to efficiently collect visible photons emitted by the phosphor screen; and (3) a charge coupled device image sensor to obtain the visible light image. From the analysis of signal and noise propagation, the system is not X-ray quantum-limited, rather the system has secondary quantum sink at the light collecting stage. The construction of the system, theoretical and experimental analysis of performance are presented.
Keywords
Flash X-ray , Intensifying screen , CCD camera , Digital imaging system