Title of article
Development of a new photomultiplier tube with high sensitivity for a wavelength-shifter fiber readout
Author/Authors
Itaya، نويسنده , , M and Inagaki، نويسنده , , T and Iwata، نويسنده , , T and Lim، نويسنده , , G.Y and Oishi، نويسنده , , H and Okuno، نويسنده , , H and Tajima، نويسنده , , Y and Yoshida، نويسنده , , H.Y and Yoshimura، نويسنده , , Y، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
10
From page
477
To page
486
Abstract
We have developed a new photomultiplier tube (PMT) with high sensitivity for a wavelength-shifter fiber readout of plastic scintillators. Improvements of the photoelectron yield were made on a 2-in. PMT (Hamamatsu R329) by adopting (1) a prism-shaped photocathode, (2) an extended-green photocathode material, and (3) an optical mirror surface of the electrodes. As a result, the number of photoelectrons obtained by the new PMT has increased to be 1.8-times that by R329. Other PMT characteristics, such as uniformity of sensitivity, time response and darkcurrent are not so much different from those of R329 for practical applications.
Keywords
Photomultiplier tube (PMT) , Prism photocathode , Wavelength-shifter (WLS) fiber readout , time response , Quantum efficiency (QE) , Darkcurrent