Title of article :
A study of a MICROMEGAS detector with a new readout scheme
Author/Authors :
Kane، نويسنده , , S. J. May، نويسنده , , Ryan J. and Miyamoto، نويسنده , , J. and Shipsey، نويسنده , , I.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
4
From page :
215
To page :
218
Abstract :
A new MICROMEGAS detector readout scheme that protects the readout electronics from damage caused by discharge initiated by large gas amplification has been studied. In the new method, the signal is produced by a readout plane placed below the MICROMEGAS detector anodes. The ratio of the signal amplitude on the readout plane was more than 65% of the signal amplitude on the cathode of the MICROMEGAS.
Keywords :
Micromegas , Discharge
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2003
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2199270