• Title of article

    Data acquisition system for BLM at NSRL

  • Author/Authors

    Gong، نويسنده , , Guanghua and Li، نويسنده , , Yuxiong and Cui، نويسنده , , Yonggang and Li، نويسنده , , Juexin and Li، نويسنده , , Weiming and Shao، نويسنده , , Beibei، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    4
  • From page
    362
  • To page
    365
  • Abstract
    A Beam Loss Monitoring (BLM) System has been built up for the 800 MeV storage ring in National Synchrotron Radiation Laboratory. It has helped to resolve some problems about beam lifetime. This paper introduces the data acquisition system of BLM. It has a counter whose counting rate is higher than 10 MHz. Furthermore, this counter is a free running one that will never lose any pulse when it is being read or written. This DAQ system is composed of 14 front-ends and a console connected via CAN bus. The intensity, distribution and time information of the beam loss can be offered by this system. This BLM system is helpful for machine study and operation.
  • Keywords
    CPLD , Beam loss monitoring , DAQ , CAN
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2003
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2199311