Title of article :
Cold electronics for the liquid argon hadronic end-cap calorimeter of ATLAS
Author/Authors :
Ban، نويسنده , , J. and Brettel، نويسنده , , H. and Cwienk، نويسنده , , W.D. and Fent، نويسنده , , J. and Kurchaninov، نويسنده , , L. and Ladygin، نويسنده , , E. and Oberlack، نويسنده , , H. and Schacht، نويسنده , , Thomas P. and Stenzel، نويسنده , , H. and Strizenec، نويسنده , , P.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
11
From page :
158
To page :
168
Abstract :
This paper describes the on-detector electronics of the ATLAS hadronic end-cap calorimeter (HEC). The electronics is operated in liquid argon; therefore attention is paid to its performance at low temperatures. The core of the electronics are Gallium Arsenide (GaAs) preamplifiers. We present design, layout and results of various tests of the preamplifier chips and summing boards. The calibration and signal cables have been studied under laboratory conditions and the signal distortion is modeled. All parts of the electronics have been produced, tested and assembled on the calorimeter modules. The summary of the commissioning tests is presented.
Keywords :
Low temperature electronics , GaAs amplifier , Front-end
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2006
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2199517
Link To Document :
بازگشت