• Title of article

    Pulse shape analysis in segmented detectors as a technique for background reduction in Ge double-beta decay experiments

  • Author/Authors

    Elliott، نويسنده , , S.R. and Gehman، نويسنده , , V.M. and Kazkaz، نويسنده , , K. and Mei، نويسنده , , D.-M. and Young، نويسنده , , A.R.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    7
  • From page
    504
  • To page
    510
  • Abstract
    The need to understand and reject backgrounds in Ge-diode detector double-beta decay experiments has given rise to the development of pulse shape analysis in such detectors to discern single-site energy deposits from multiple-site deposits. Here, we extend this analysis to segmented Ge detectors to study the effectiveness of combining segmentation with pulse shape analysis to identify the multiplicity of the energy deposits.
  • Keywords
    76Ge , Neutrinoless double-beta decay , Ge detectors , Pulse shape analysis , segmentation
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2006
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2199818