Abbrescia، نويسنده , , M. and Altieri، نويسنده , , S. and Baratti، نويسنده , , V. and Barnabà، نويسنده , , O. and Belli، نويسنده , , G. and Bruno، نويسنده , , G. and Colaleo، نويسنده , , A. and De Vecchi، نويسنده , , C. and Guida، نويسنده , , R. and Iaselli، نويسنده , , G. and Imbres، نويسنده , , E. and Loddo، نويسنده , , F. and Maggi، نويسنده , , M. and Marangelli، نويسنده , , B. and Musitelli، نويسنده , , G. and Nardٍ، نويسنده , , R. and Nat، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
4
From page :
79
To page :
82
Abstract :
RPC neutron sensitivity has been studied during two tests done with different neutrons energies. In the first test, neutrons from spontaneous fission events of 252Cf were used (average energy 2 MeV); while in the second test neutrons were produced using a 50 MeV deuteron beam on a 1 cm thick beryllium target (average energy 20 MeV). Preliminary results show that the neutron sensitivity in double gap mode is (0.52±0.03)×10−3 at about 2 MeV and (5.3±0.5)×10−3 at about 20 MeV.
Keywords :
gamma sensitivity , Neutron sensitivity , Compact muon solenoid , Resistive plate chamber