Title of article :
Development of integrated subcriticality-monitoring system for ADS and experimental verification by using STACY
Author/Authors :
Gunji، نويسنده , , Satoshi and Iwasaki، نويسنده , , Tomohiko and Miyoshi، نويسنده , , Yoshinori and Nishihara، نويسنده , , Kenji، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
In order to operate accelerator driven subcritical system safely, it is necessary to monitor the subcriticality in real-time. In this paper, we propose a highly accurate real-time subcriticality-monitoring system by combining the existing multiple measurement techniques, a number of neutron detectors, and computations. Combining the advantages of each technique and averaging among the multiple measurements, the system provides high accurate subcriticality in real-time. This system was examined by subcritical experiments using STAtic experiment Critical facilitY. The experimental results showed that the subcriticalities of the results of this system agreed with the reference values, and it showed the system is useful as a real-time monitor.
Keywords :
ADS , MVP , STACY , Subcriticality monitor
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A