Title of article :
Performances of the CsI(Tl) detector element of the GLAST calorimeter
Author/Authors :
Bédérède، نويسنده , , D. and Bougamont، نويسنده , , E. and Bourgeois، نويسنده , , Ph. and Gentit، نويسنده , , F.X. and Piret، نويسنده , , Y. and Tauzin، نويسنده , , G.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
The CsI(Tl) Detector Element (CDE) is the unit of detection of the calorimeter subsystem of the Large Area Telescope (LAT) of the GLAST satellite (IEEE Nuclear Science Symposium, 2002), which will be launched in September 2006. The LAT consists of 4×4 identical towers, each one including a strip silicon tracker on the top and a CsI(Tl) calorimeter on the bottom. A segmented plastic scintillator anticoincidence detector surrounds the 16 towers. The calorimeter modules, 8 layers of 12 CDEs each, have a hodoscopeʹs shape to allow the measurement of the gamma-ray direction.
E main characteristics are its Light Yield, the energy resolution and the tapering, ratio of left/right signals used for the determination of the crossing position of the particle in the crystal.
E have to operate in space at about −10°C. We will describe the CDE, the optimization of its main parameter, the L.Y., and finally its variation with temperature.
Keywords :
Calorimeter , CsI(Tl) , Light yield , Reflective material , VM2000 , PIN Photodiode
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A