• Title of article

    Large-scale production of Monitored Drift Tube chambers for the ATLAS muon spectrometer

  • Author/Authors

    Bauer، نويسنده , , F. and Horvat، نويسنده , , S. and Kortner، نويسنده , , O. and Kroha، نويسنده , , H. and Manz، نويسنده , , A. and Mohrdieck، نويسنده , , S. and Richter، نويسنده , , R. and Zhuravlov، نويسنده , , V.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    4
  • From page
    69
  • To page
    72
  • Abstract
    Precision drift tube chambers with a sense wire positioning accuracy of better than 20 μm are under construction for the ATLAS muon spectrometer. 70% of the 88 large chambers for the outermost layer of the central part of the spectrometer have been assembled. Measurements during chamber construction of the positions of the sense wires and of the sensors for the optical alignment monitoring system demonstrate that the requirements for the mechanical precision of the chambers are fulfilled.
  • Keywords
    Drift chambers , Drift tubes , ATLAS detector , Muon Spectrometer
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2004
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2201045