• Title of article

    Optimised k0-instrumental neutron activation method using the TRIGA MARK I IPR-R1 reactor at CDTN/CNEN, Belo Horizonte, Brazil

  • Author/Authors

    Menezes، نويسنده , , M.A.B.C. and Ja?imovi?، نويسنده , , R.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    9
  • From page
    707
  • To page
    715
  • Abstract
    The Nuclear Technology Development Centre/Brazilian Commission for Nuclear Energy, CDTN/CNEN, is the only Brazilian Institution to apply the k0-standardisation method of instrumental neutron activation technique determining elements using its own nuclear reactor, TRIGA MARK I IPR-R1. After changes in the reactor core configuration, the reactor neutron flux distribution in typical irradiation channels had to be updated, as well as the parameters f and α, needed to apply the k0-method of neutron activation analysis. The neutron flux distribution in the rotary rack was evaluated through the specific count rate of 198Au and the parameters f and α, were determined in five selected channels applying the “Cd-ratio for multi-monitor” method, using a set of Al-(0.1%)Au and Zr (99.8%) monitors. Several reference materials were analysed, indicating the effectiveness of the improved method.
  • Keywords
    NEUTRON ACTIVATION ANALYSIS , K0-standardisation , detector calibration , reference materials
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2006
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number