  • Abstract
    This work presents a Monte Carlo study of the cylindrical cobalt source rack geometry of the Tunisian gamma irradiation facility, using the GEANT code developed at CERN. The study investigates the question of the reload of the source rack. The studied configurations consist in housing four new cobalt pencils, two in the upper and two in the lower cylinder of the source rack. Global dose rate uniformity inside a “dummy” product for the case of routine and nonroutine irradiation, and as function of the product bulk density, was calculated for eight hypothetical configurations. The same calculation was also performed for both of the original and the ideal (but not practical) configurations. It was shown that hypothetical cases produced dose uniformity variations, according to product density, that were statistically no different than the original and the ideal configurations and that the reload procedure cannot improve the irradiation quality inside the facilities using cylindrical cobalt source racks.
  • Keywords
    Reload , Cylindrical source rack , Dose uniformity , Monte Carlo , GEANT