Title of article :
SCUBA-2 arrays to system interfaces
Author/Authors :
Duncan ، نويسنده , , W and Audley، نويسنده , , D and Holland، نويسنده , , W and Atkinson، نويسنده , , D and Baillie، نويسنده , , T and Cliffe، نويسنده , , M and Ellis، نويسنده , , M and Gao، نويسنده , , X and Gostick، نويسنده , , D and Hodson، نويسنده , , T and Kelly، نويسنده , , D and MacIntosh، نويسنده , , M and McGregor، نويسنده , , H and Peacocke، نويسنده , , T and Smith، نويسنده , , I and Robson، نويسنده , , I and Walton، نويسنده , , A and Parkes، نويسنده , , W and Dunare، نويسنده , , C and Smith، نويسنده , , S and Terry، نويسنده , , J and Stevenson، نويسنده , , T and Gundlach، نويسنده , , A and Ruthven، نويسنده , , A and Ade، نويسنده , , P and Tucker، نويسنده , , C and Gannaway، نويسنده , , F and Walker، نويسنده , , I and Sudiwala، نويسنده , , R and Woodcraft، نويسنده , , A and Griffin، نويسنده , , M and Bintley، نويسنده , , D and Schulte، نويسنده , , E and Fich، نويسنده , , M and Kycia، نويسنده , , J and Halpern، نويسنده , , M and Molnar، نويسنده , , J and Burger، نويسنده , , B and Naylor، نويسنده , , D and Bastien، نويسنده , , P and Mitchell، نويسنده , , G and Irwin، نويسنده , , K and Hilton، نويسنده , , G and Ullom، نويسنده , , J and Reintsema، نويسنده , , C and Vale، نويسنده , , L and Ferreira، نويسنده , , L and Doriese، نويسنده , , W، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
4
From page :
427
To page :
430
Abstract :
Submillimeter common user bolometer array (SCUBA)-2 is a wide field sub-mm bolometer camera designed to replace the existing SCUBA instrument on the JCMT in Hawaii. It will be many hundreds of times faster in large area mapping than SCUBA and will also go deeper in a single frame. It will enable the many discoveries of SCUBA to be followed up with deep systematic surveys and help act as a pathfinder for the ALMA interferometer. The key technologies for making the arrays have been demonstrated and will be put together to fabricate the first prototype later this year (2003). The wide field nature of the SCUBA-2 bolometer camera, combined with the diffraction limit at sub-mm wavelengths, leads to physically large focal planes where the issues of stray light control, magnetic shielding, and electrical, thermal and mechanical connection must be carefully addressed in order to realise a successful instrument. We describe the solutions we have adopted for these problem areas.
Keywords :
Niobium flex , Array interfaces , SCUBA-2 , SQUID multiplexer
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2004
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2201910
Link To Document :
بازگشت