Title of article :
The charge state distribution of Be, C, Cl and Al ions at the Lund Pelletron accelerator with the recently modified terminal pumping in use
Author/Authors :
Kiisk، نويسنده , , Madis and Hellborg، نويسنده , , Ragnar and Persson، نويسنده , , Per and Faarinen، نويسنده , , Mikko and Skog، نويسنده , , Gِran and Stenstrِm، نويسنده , , Kristina، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
7
From page :
299
To page :
305
Abstract :
Some years ago terminal pumping for the gas stripper system at the 3 MV Lund Tandem Pelletron accelerator was installed and charge state distribution measurements using the new installation were reported. Since then, new modifications of the mechanical design of the stripper system have been made. The results of pressure profile measurements as well as the results of charge state distribution measurements in a N2 and Ar gas stripper at different, new geometrical modifications of the stripper system using C, Be, Al and Cl ion beams are reported. arison between pressure profiles obtained for different geometries shows a clear improvement of the vacuum conditions outside the stripper housing for the smallest conductance pipes between the stripper system and the accelerator tubes. These improvements are also well reflected in the charge state distribution measurements, as a higher mean charge state is obtained under the same vacuum conditions in the accelerator tubes for the improved stripper system in comparison with the former mechanical design.
Keywords :
Tandem accelerator , Pressure profile , Charge state distribution , Terminal pumping
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2004
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2202109
Link To Document :
بازگشت