Title of article :
Removal of scattered thermal neutrons using antiscatter grid
Author/Authors :
Mandour، نويسنده , , M.A. and Shaat، نويسنده , , M.K. and Badawi، نويسنده , , A.A. and Mongy، نويسنده , , T. and Mohamed، نويسنده , , Nader.M.A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
One of the significant factors of neutron radiographic image degradation is scattering blur from the object. A practical method is described to enhance image quality by eliminating the overlapping of scattered thermal neutrons component from the objects in ETRR-2 neutron radiography facility, using aluminum Gd-coated antiscatter grid. The MCNP code was used to determine the optimum grid dimensions that will reduce the scattered thermal neutrons from the object. An experiment was performed to determine the optimum grid height and irradiation time that gives the best image with acceptable geometric unsharpness. Using the MCNP code it was found that 97% of the scattered neutrons were removed by the grid. The wall dimensions and Gd coating are so small that the facility resolution cannot detect the image pattern superposition on the film.
Keywords :
Thermal neutron , Scattering correction , Antiscatter grid , Scattering blur , Geometric unsharpness , Image degradation
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A