Title of article
Charge equalizing and error estimation in position sensitive neutron detectors
Author/Authors
Bِnisch، نويسنده , , Sven P. and Namaschk، نويسنده , , Bernhard and Wulf، نويسنده , , Friedrich، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
7
From page
133
To page
139
Abstract
The conventional design of detector electronics for resistive wire position sensitive neutron detectors (PSD) using of-the-shelf charge sensitive preamplifiers and gauss-pulse shaping devices causes uncertainty in spatial position and resolution due to charge equalization between both ends of the resistive PSD. This paper describes in detail charge equalization effects and their drawbacks for a PSD system design. Error estimations for a conventional design are given. Attained results should help to better understand PSD electronics design and to provide data for system optimization.
Keywords
Charge equalization , PSD , Spatial position , Resistive wire position sensitive neutron detector , error estimation , RESOLUTION , Pulse shaping
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2007
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2202422
Link To Document