Title of article :
Monte Carlo evaluation of the muon-induced background in the GERDA double beta decay experiment
Author/Authors :
Pandola، نويسنده , , L. and Bauer، نويسنده , , M. and Krِninger، نويسنده , , K. and Liu، نويسنده , , X. and Tomei، نويسنده , , C. and Belogurov، نويسنده , , S. and Franco، نويسنده , , D. and Klimenko، نويسنده , , A. and Knapp، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
10
From page :
149
To page :
158
Abstract :
The new generation of experiments searching for neutrinoless double beta decay is aiming at a background level of 10 - 3 counts / ( kg keV y ) or better at the respective Q-values. Cosmic ray muons can be a significant contribution due to a number of physics processes. The GERmanium Detector Array, GERDA, located at the Gran Sasso underground laboratory in Italy, uses germanium enriched in 76Ge as source and detector material. Germanium is submerged into liquid nitrogen or argon that acts as cooling medium and radiation shield simultaneously. A detailed Geant4-based Monte Carlo simulation was performed to calculate the photon and neutron fluxes induced by cosmic ray muons. The prompt background contributions from γ -ray and neutron interactions as well as the delayed contributions due to the production of radioactive isotopes within the setup are given. The background can be reduced to the desired level with the muon veto system incorporated in the GERDA design.
Keywords :
Cosmic ray background , Neutrinoless double beta decay
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2007
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2202424