Author/Authors :
Alfonsi، نويسنده , , M and Bencivenni، نويسنده , , G and de Simone، نويسنده , , P and Murtas، نويسنده , , F and Poli Lener، نويسنده , , M and Bonivento، نويسنده , , W and Cardini، نويسنده , , A and Deplano، نويسنده , , C and Pinci، نويسنده , , D and Raspino، نويسنده , , D and Saitta، نويسنده , , B، نويسنده ,
Abstract :
We show that adding CF4 to the standard Ar/CO2 gas mixture allows to substantially improve the time resolution of triple-GEM detectors.
s paper we discuss measurements of time resolution, discharge probability per incident charged particle and pad multiplicity of a triple-GEM detector with pad readout, with new gas mixtures with CF4 and isobutane.
s for detectors with GEM foil size of both 10×10 cm2 and 20×24 cm2 are presented.
Keywords :
GEM , Tracking , ageing , Discharge