Title of article :
Methods to extract more light from minute scintillation crystals used in an ultra-high resolution positron emission tomography detector
Author/Authors :
Levin، نويسنده , , Craig S and Habte، نويسنده , , Frezghi and Foudray، نويسنده , , Angela M، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
Recently, there has been great interest in developing finely pixellated position-sensitive scintillation detectors for ultra-high-resolution Positron Emission Tomography (PET) systems designed for breast cancer detection, diagnosis, and staging and for imaging small laboratory animals. We are developing a different high-resolution PET detector design that promotes nearly complete scintillation light collection in ⩽1 mm wide, >10 mm thick lutetium oxyorthosilicate (LSO) crystals. The design requires the use of semiconductor photodetector arrays in novel configurations that significantly improve the light collection aspect ratio for minute crystals. To reduce design complexity and dead area we are investigating the use of 1 mm thick sheets of LSO in addition to discrete crystal rods, and the use of position-sensitive avalanche photodiodes (PSAPDs) which require only four readout channels per device, in addition to pixellated APD arrays. Using a 1 mm thick scintillation crystal sheet coupled to a finely pixellated APD array results in a pseudo-discrete response to flood irradiation: due to a very narrow light spread function in the thin sheet we observe sharp (<1 mm wide) peaks in sensitivity centered at the APD pixel locations in a very linear fashion all the way out to the crystal edge. We measured an energy resolution of 13.7% FWHM at 511 keV for a 1 mm LSO crystal coupled to two APD pixels. Using a 1 mm thick crystal sheet coupled to a PSAPD the response to flood and edge-on irradiation with a 22Na point source shows a compressed dynamic range compared to that observed with discrete crystals or direct X-ray irradiation. With a discrete LSO crystal array the flood response is peaked at the crystal location where light is focused onto one spot on the PSAPD. We observed strong pin-cushioning effects in all PSAPD measurements. All LSO–PSAPD configurations studied had high aspect ratio for light collection and achieved energy resolutions ⩽12% FWHM at 511 keV.
Keywords :
High-resolution PET , breast imaging , Small animal PET , Avalanche photodiode , Scintillation light collection
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A