Author/Authors :
V. and Artikov، نويسنده , , A. and Budagov، نويسنده , , J. and Chirikov-Zorin، نويسنده , , I. and Chokheli، نويسنده , , D. and Kolomoets، نويسنده , , V. and Lyablin، نويسنده , , M. and Pukhov، نويسنده , , O. and Sissakian، نويسنده , , James A. and Bellettini، نويسنده , , G. and Cervelli، نويسنده , , F. and Incagli، نويسنده , , M. and Menzione، نويسنده , , A. and Palmonari، نويسنده , , F. and Scribano، نويسنده , , A. M. Stefanini، نويسنده , , A، نويسنده ,
Abstract :
New scintillation counters have been designed and constructed for the upgradation of the CDF detector at the Fermilab Tevatron in order to complete the muon coverage of the central detector and to extend it to a larger pseudorapidity interval. A novel light collection technique using wavelength shifting fibers, together with high-quality polystyrene-based scintillator resulted in compact counters with good and stable light collection efficiency over lengths extending up to 320 cm. Their design and construction is described and results of their initial performance are reported.
Keywords :
Photoelectron , CDF , amplifier , Scintillation counter , Muon , Magnetic field , optical , Photomultiplier