Title of article :
High-rate particle identification of high-energy heavy ions using a tilted electrode gas ionization chamber
Author/Authors :
Kimura، نويسنده , , K. and Izumikawa، نويسنده , , T. and Koyama، نويسنده , , R. and Ohnishi، نويسنده , , T. and Ohtsubo، نويسنده , , T. and Ozawa، نويسنده , , A. and Shinozaki، نويسنده , , W. and Suzuki، نويسنده , , T. and Takahashi، نويسنده , , M. and Tanihata، نويسنده , , I. and Yamaguchi، نويسنده , , T. and Yamaguchi، نويسنده , , Y.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
7
From page :
608
To page :
614
Abstract :
A high-rate particle identification device for high-energy heavy ions has been developed which utilizes a stacked configuration of grid-less parallel plate gas ionization chambers with thin anode–cathode gaps. The high-rate capability of this chamber was realized by adopting bipolar shaping of anode signals and by the suitable choice of a counter gas. Z-resolutions of 0.2–0.3 were obtained for nuclear fragments of Ar 40 at 95 A MeV with an intensity as high as 10 6 cps .
Keywords :
heavy ion , Particle identification , Gas ionization chamber
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2005
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2203098
Link To Document :
بازگشت