Title of article
Optimization of a neutron image plate detector with low γ-sensitivity
Author/Authors
Masalovich، نويسنده , , S. and Ioffe، نويسنده , , A. and Schlapp، نويسنده , , M. and von Seggern، نويسنده , , H. and Küssel، نويسنده , , E. and Brückel، نويسنده , , Th.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
14
From page
236
To page
249
Abstract
Recent experimental studies on new materials (storage phosphors and neutron converter) to be used in a low γ -sensitive neutron image plate detector have been performed at the Research Center Jülich and Darmstadt University of Technology. It was shown that a mixture LiF+KCl:Eu2+ (or KBr:Eu2+) features a higher neutron/gamma signal ratio compared to BaFBr:Eu2+mixed with Gd as in commercially available neutron image plates. However, the smaller neutron capture cross-section of 6Li in comparison with Gd requires the use of significantly thicker recording layers. This article presents the results of numerical estimations for the performance of such a detector. The use of image plates with a thick recording layer and a regular cell structure allowing for the increase in spatial resolution (pixelated image plate) is discussed.
Keywords
Detector Efficiency , Pixelated detector , neutron detector , Image plate