Title of article
Tangential FEB diagnostic in the HT-7 Tokamak
Author/Authors
Chen، نويسنده , , Z.Y and Wan، نويسنده , , B.N and Shi، نويسنده , , Y.J and Hu، نويسنده , , L.Q. and Lin، نويسنده , , S.Y. and Ding، نويسنده , , Y.H.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
6
From page
602
To page
607
Abstract
Fast electron bremsstrahlung (FEB) emission during lower hybrid current drive experiments on the HT-7 superconducting tokamak has been measured by a recently developed tangential multi-channel FEB diagnostic based on CdTe detectors. There are 14 sight lines to observe the forward parallel emission of fast electrons with spatial resolution of 4 cm and 6 sight lines to observe the backward parallel emission of fast electrons with spatial resolution of 8 cm. The FEB emission in the energy range of 30–400 keV can be measured. In this paper, the tangential FEB diagnostic is described, and the preliminary experimental results of FEB emission measurements are presented.
Keywords
Fast electron , CdTe , FeB , tokamak
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2005
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2203453
Link To Document