Title of article
Study of a non-intercepting ion beam diagnostic for beam density profile
Author/Authors
Roy، نويسنده , , P.K. and Yu، نويسنده , , S.S. and Eylon، نويسنده , , S. and Henestroza، نويسنده , , E. and Ludvig، نويسنده , , J. and Shuman، نويسنده , , D.B. and Greenway، نويسنده , , W.G. and Vanecek، نويسنده , , D.L. and Waldron، نويسنده , , W.L. and Hannink، نويسنده , , Ryan and Bieniosek، نويسنده , , F.M.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
7
From page
520
To page
526
Abstract
An electron beam diagnostic system for measuring the charge distribution of an ion beam without changing its properties is investigated. The conceptual basis of the diagnostic, the design and setup of the system, characterization of the mechanical construction, electron beam transport and its deflection with an ion beam is presented.
Keywords
e-beam probe , Beam transport , Chicane magnet , Diagnostic , Electron gun
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2005
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2203577
Link To Document