Title of article
Radiation test on FD-SOI readout ASIC of pair-monitor for ILC
Author/Authors
Sato، نويسنده , , Yutaro and Arai، نويسنده , , Yasuo and Ikeda، نويسنده , , Hirokazu and Nagamine، نويسنده , , Tadashi and Takubo، نويسنده , , Yosuke and Tauchi، نويسنده , , Toshiaki and Yamamoto، نويسنده , , Hitoshi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
5
From page
106
To page
110
Abstract
The pair-monitor is a silicon pixel device that measures the beam profile at the interaction point of the International Linear Collider. It extracts information from the directional distribution of a large number of electron–positron pairs created by collision of bunches, and is required to tolerate radiation dose of about a few Mrad/year. We developed a prototype ASIC with OKI Semiconductor Co., Ltd. 0.2 - μ m fully depleted SOI (FD-SOI) CMOS process and studied its radiation tolerance. In this paper, we describe the design of the readout circuit briefly and present the result of irradiation tests.
Keywords
Readout ASIC , iLC , Pair-monitor , SOI , Beam profile , Irradiation