Title of article
Design, measurement and correction of a pair of novel focusing undulators for the ALPHA-X project
Author/Authors
Shepherd، نويسنده , , Benjamin J.A. and Clarke، نويسنده , , James A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
10
From page
8
To page
17
Abstract
ALPHA-X is a UK collaboration to develop and build a prototype laser-plasma accelerator. The ALPHA-X beam line generates an electron bunch with energy 0.1–1 GeV; this is injected into a pair of permanent magnet undulators to generate a short pulse of radiation. The design of the undulators is detailed in this paper.
dulators have a requirement to focus the beam along their length. Several focusing schemes were analysed. The scheme used involved magnet blocks with a 5×1 mm slot cut into the top to provide a sextupole-type field.
dulators were built and tested at STFCʹs Daresbury Laboratory. Some block swapping was carried out for each one to reduce the overall field integrals and optimise the beam transport. The first field integral was reduced using this technique to less than 0.1 T mm for both undulators.
Keywords
Undulator , Magnet measurement , Hall probe , Permanent Magnet
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2011
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2204856
Link To Document