Title of article :
Enhanced quantum efficiency bialkali photo multiplier tubes
Author/Authors :
Mirzoyan، نويسنده , , Razmick and Goebel، نويسنده , , Florian and Hose، نويسنده , , Juergen and Hsu، نويسنده , , Ching Cheng and Ninkovi?، نويسنده , , Jelena and Paneque، نويسنده , , David and Rudert، نويسنده , , Agnes and Teshima، نويسنده , , Masahiro، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
Currently, the classical PMTs with semitransparent bialkali photo cathode show peak quantum efficiency (QE) of ∼25–27%. Although the above-mentioned peak QE was achieved already ∼40 years ago, nevertheless one cannot report any significant increase since then. A couple of years ago we started a development program with the main PMT manufacturers Photonis, Electron Tubes and Hamamatsu, aiming to boost-up the peak QE of the (1–2)″ size bialkali PMTs. Today we want to report that our efforts were successful: all of the three above-mentioned companies succeeded to boost the peak QE of bialkali PMTs to the level of 30–35%. In this report, we want to show the QE measurements of different tubes and discuss the future prospects. For example, it shall be possible to use the diffuse-scattering matt lacquer coating technique in order to enhance further the QE. In our previous experience application of that coating provided ∼15% increase in QE for 1–1.5″ hemispherical tubes.
Keywords :
Quantum efficiency , Bialkali photo cathodes , Photo multiplier tubes , Low light level sensors , Light sensors
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Journal title :
Nuclear Instruments and Methods in Physics Research Section A