• Title of article

    High voltage system for the CMS forward calorimeter

  • Author/Authors

    Akchurin، نويسنده , , N. and Atramentov، نويسنده , , O. and Dimitrov، نويسنده , , L. and Hauptman، نويسنده , , J. and Kim، نويسنده , , H. and Los، نويسنده , , S. and Sergeev، نويسنده , , S. and Vankov، نويسنده , , I.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    6
  • From page
    618
  • To page
    623
  • Abstract
    The power supply system developed for the photomultipliers (PMTs) of the forward calorimeter (HF) of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider is described. The 1728 PMTs of the HF are divided into 24 clusters of 72 with similar gain value. All of the PMTs within each cluster are powered by the same three high voltage (HV) power supplies, making a total of only 72 power supplies in the entire system. In this so-called parallel dynode voltage distribution, the three HV power supplies can be adjusted from 0 to −2000, −800, and −400 V, respectively. All output voltages are floating to facilitate a single-point ground configuration. The system is computer controlled and integrated into the CMS detector slow control facility.
  • Keywords
    Calorimeter , Photomultiplier , Power supply system
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2007
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2205307