Title of article
Detailed study of the gain of the MWPCs for the LHCb muon system
Author/Authors
Dané، نويسنده , , E. and Penso، نويسنده , , G. and Pinci، نويسنده , , D. and Sarti، نويسنده , , A.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
7
From page
682
To page
688
Abstract
The gain of a multiwire proportional chamber (MWPC) of the LHCb muon detector was measured precisely. The chamber, filled with a CO 2 / Ar / CF 4 gas mixture, 55/40/5% in volume, was irradiated with a 1.3 GBq 137Cs radioactive source and the current drawn by the chamber was measured. By precisely determining the primary ionization current it was possible to evaluate the absolute gain of the chamber. The dependence of the gain on the anode voltage and the gas density was measured and the need for a gain control system during the LHCb data taking is considered. Our experimental results are compared with those predicted for the chamber gain by Diethorn formula.
Keywords
Multiwire proportional chambers , Tracking and position-sensitive detectors , Elementary-particle and nuclear physics experimental methods and instrumentation
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Serial Year
2007
Journal title
Nuclear Instruments and Methods in Physics Research Section A
Record number
2205322
Link To Document