• Title of article

    Dynamic magnetic shield for the CLAS12 central TOF detector photomultiplier tubes

  • Author/Authors

    Baturin، نويسنده , , V. D. Burkert، نويسنده , , V. and Carman، نويسنده , , D.S. and Elouadrhyri، نويسنده , , L. and Grilli، نويسنده , , D. and Kashy، نويسنده , , D. and Pasyuk، نويسنده , , E. and Quettier، نويسنده , , L. and Wieland، نويسنده , , B.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    11
  • From page
    11
  • To page
    21
  • Abstract
    The Central Time-of-Flight detector for the Jefferson Laboratory 12-GeV upgrade is being designed with linear-focused photomultiplier tubes that require a robust magnetic shield against the CLAS12 main 5-T solenoid fringe fields of 100 mT (1 kG). Theoretical consideration of a ferromagnetic cylinder in an axial field has demonstrated that its shielding capability decreases with increasing length. This observation has been confirmed with finite element analysis using POISSON model software. Several shields composed of coaxial ferromagnetic cylinders have been studied. All difficulties caused by saturation effects were overcome with a novel dynamical shield, which utilizes a demagnetizing solenoid between the shielding cylinders. Basic dynamical shields for ordinary linear-focused 2-in. photomultiplier tubes were designed and tested both with models and experimental prototypes at different external field and demagnetizing current values. Our shield design reduces the 1 kG external axial field by a factor of 5000.
  • Keywords
    JLab , Time-of-flight , Photomultiplier tube , Magnetic shield , CLAS
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Serial Year
    2012
  • Journal title
    Nuclear Instruments and Methods in Physics Research Section A
  • Record number

    2205536