Title of article :
An analysis of microchannel plate composition and its effect on extreme ultraviolet quantum efficiency
Author/Authors :
Carpenter، نويسنده , , James D. and Fraser، نويسنده , , George W. and Bannister، نويسنده , , Nigel P. and Fairbend، نويسنده , , R.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
4
From page :
232
To page :
235
Abstract :
Modern microchannel plate detectors exhibit low quantum efficiency in the extreme ultra violet range compared to those manufactured before 1990. The cause of this reduction in efficiency is unknown. We describe recent investigations into the along-channel surface compositions of a number of microchannel plates (MCPs) of varying efficiency. These compositional profiles, generated using energy-dispersive X-ray spectroscopy, provide insight into possible mechanisms underlying the efficiency reduction and may assist in efforts to restore good extreme ultraviolet (EUV) performance to MCPs through modifications to the manufacturing process.
Keywords :
Microchannel plate (MCP) , Extreme ultraviolet (EUV) , Quantum efficiency (QE) , X-ray fluorescence (XRF)
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Serial Year :
2007
Journal title :
Nuclear Instruments and Methods in Physics Research Section A
Record number :
2205567