Title of article :
Results of irradiation quality assurance of CMS silicon microstrip detectors
Author/Authors :
Furgeri، نويسنده , , Alexander J. and de Boer، نويسنده , , David W. and Hartmann، نويسنده , , F.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
The Large Hadron Collider (LHC) at CERN is a proton–proton collider with a maximum luminosity of 10 34 / cm 2 s and will be working for 10 years. The Compact Muon Solenoid (CMS) will be one of the two general purpose detectors. In order to guarantee the functionality of the 24 328 single-sided silicon sensors in the heavy irradiation environment of the LHC a fraction of all sensors have been irradiated in the two Irradiation Qualification Centers (IQC) in Karlsruhe (Germany) and Louvain-la-Neuve (Belgium). In Karlsruhe the sensors are irradiated with 26 MeV protons and in Louvain-la-Neuve they are irradiated with a neutron spectrum with an average energy of 20 MeV. The following sections show observed coupling capacitances, bias resistances and interstrip capacitances before and after irradiation and after varying annealing times at 60 ∘ C .
Keywords :
Radiation hardness , Leakage Current , signal to noise ratio , Poly-crystalline silicon resistor , Tracker , Coupling capacitance , Interstrip capacitance , CMS